;************************************************************************* ;*** *** ;*** Götting KG *** ;*** D-31275 Lehrte-Röddensen *** ;*** Celler Straße 5 *** ;*** Tel: 05136/8096-0 *** ;*** Fax: 05136/8096-80 *** ;*** *** ;************************************************************************* ;*** *** ;*** Filename: HG17100A1.GSD (c) 2003 *** ;*** GSD file version 1 from 22.07.2003 *** ;*** *** ;************************************************************************* ; ; ATTENTION: ; ========== ; Changes in this file can cause configuration or communication problems. ; This file is compatible to the firmware of the device. #Profibus_DP GSD_Revision = 1 Vendor_Name = "Götting KG" Model_Name = "HG17100-A" Revision = "Version 1.00" Ident_Number = 0x3003 Protocol_Ident = 0 Station_Type = 0 Hardware_Release = "HG17100" Software_Release = "17100A1 V1.00" Implementation_Type = "SPC3" 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 0 User_Prm_Data_Len = 2 User_Prm_Data = 0x00,0x01 Min_Slave_Intervall = 11 Modular_Station = 0 Max_Diag_Data_Len = 244 Slave_Family = 3 Module = "2 Byte Input/1 Byte Output" 0x11, 0x20 EndModule